AHU Refurbishment

Restore & extend
your air handling units.

01256 518170

Extend your AHU's life by 10–20+ years at around 40% of full replacement cost.

40+

Yrs Experience

All Manufacturers

Covered

UK Wide

Coverage

Trusted by leading organisations

NHSDisneyMarriott HotelsMoorfields Eye HospitalIHG Hotels & ResortsTravelodgeWaitroseWestfieldFenwickFreedom LeisureQueen Mary UniversityAlpine F1 TeamNHSDisneyMarriott HotelsMoorfields Eye HospitalIHG Hotels & ResortsTravelodgeWaitroseWestfieldFenwickFreedom LeisureQueen Mary UniversityAlpine F1 Team

Common indicators

Signs Your AHU Needs Attention

01

Reduced Efficiency

The unit is no longer delivering the airflow or temperature conditions required by the building design.

02

Failure to Meet Design Requirements

Changing building use, occupancy, or regulation means the existing unit configuration can no longer comply.

03

Excessive Noise

Worn bearings, degraded fan blades, or loose components cause operational noise that was not present originally.

04

Temperature Problems

Inconsistent heating or cooling across zones points to coil degradation, control failures, or heat exchanger fouling.

05

Corrosion from Water Ingress

Condensation or drainage issues cause internal corrosion affecting structural integrity and air quality.

06

Poor Indoor Air Quality

Filter bypass, damaged seals, or degraded heat recovery reduces ventilation effectiveness and IAQ compliance.

What it involves

What Is AHU Refurbishment?

AHU refurbishment is a precise process aimed at restoring optimal functionality and efficiency. It is a comprehensive process involving thorough inspection and strategic component upgrades, not a blanket overhaul.

Our engineers carry out a detailed assessment of every major component before any works are specified or authorised:

  • Fans, coils, filters, and dampers
  • Heat recovery and heat exchangers
  • Unit corrosion and structural condition
  • AHU controls and automation interfaces
  • Access doors, panels, and seals

Only failed or degraded components are replaced. The structural frame, casing, and duct connections are retained wherever viable, keeping costs down and works in-situ.

40%

of replacement cost, typically

10–20+

additional years of asset life

40+

years of AHU experience

0

disruption preferred, phased works

Why refurbish

The Case for Refurbishment

In most cases the existing AHU casing and frame are structurally sound. A targeted refurbishment restores full performance, integrates modern efficiency improvements, and avoids the cost and disruption of full replacement.

Cost Effective

The cost to refurbish in-situ is typically around 40% of that of replacing with a new air handling unit, substantial capital savings.

Energy Saving Upgrades

Modern heat recovery controls and high-efficiency EC fans can be incorporated or retrofitted into the existing unit during refurbishment.

Industry Standard Compliant

Systems can be modified to meet current building requirements including HTM 03-01 for healthcare and Part L energy regulations.

Minimum Disruption

AHU refurbishment typically causes little or no disruption to client premises. Works are phased around operational requirements.

Extended Asset Life

This approach effectively extends the unit's working life by another 10–20+ years, deferring the capital cost of full replacement.

Enhanced Performance

Latest energy-efficient technology including direct drive plug fans and high-efficiency motors restores and improves original design performance.

Sectors

Industries We Serve

Healthcare & HospitalsHotels & LeisureCommercial OfficesRetail & Shopping CentresGyms & Sports FacilitiesEducational BuildingsManufacturing & IndustrialSwimming PoolsCommercial Kitchens

The process

Survey to Handover, Four Steps

01

Site Survey

On-site inspection by a BVS engineer confirms condition, refurbishment viability, and scope requirements, with an honest assessment.

02

Specification & Quote

Fixed, component-level scope produced and agreed before any works are authorised. No surprises.

03

Refurbishment Works

In-situ delivery by our engineers, phased to keep ventilation live where possible and programmed around your operations.

04

Test & Handover

Full commissioning, performance verification, and documentation package on completion.

BVS engineer carrying out AHU refurbishment works

Our Projects

Work We've Delivered

NHS trusts, shopping centres, hotels, entertainment venues, and production facilities.

NHS Trust AHU Refurbishment, Live Facility

Healthcare / NHS · Hammersmith, London

NHS Trust AHU Refurbishment, Live Facility

Relevant if: Your AHU is in a live clinical facility that stays operational during works, You need targeted component repair rather than full unit replacement, Reliability and indoor air quality cannot be compromised

Operating Theatre AHU Refurbishment with EC Upgrade

Healthcare / Private · Bath

Operating Theatre AHU Refurbishment with EC Upgrade

Relevant if: Theatre or clinical-grade air quality standards are required throughout, Energy reduction is part of the refurbishment brief, Works must fit around a live clinical programme

AHU Refurbishment, High-Footfall Venue

Sport & Entertainment · O2 Arena, London

AHU Refurbishment, High-Footfall Venue

Relevant if: Your venue has limited maintenance windows between events or trading hours, Works must be programmed tightly around the operational calendar, Asset life extension is preferred over full unit replacement

AHU Refurbishment, Active Production Facility

Industrial / Food & Drink · UK

AHU Refurbishment, Active Production Facility

Relevant if: Your environment has specific temperature or humidity requirements tied to production, Shutdown windows need to be planned around a production schedule, The facility remains operational during the works

Shopping Centre AHU Refurbishment & Gas Pipework

Retail / Shopping Centre · Glasgow

Shopping Centre AHU Refurbishment & Gas Pipework

Relevant if: Your AHU serves a live retail or public environment that cannot close, Belt-driven fans are overdue for upgrading, Gas distribution infrastructure also needs a compliance review

Full Internal Refurbishment, City Office AHU

Commercial Office · London

Full Internal Refurbishment, City Office AHU

Relevant if: Multiple internal components have reached end of life at the same time, Air volume requirements have changed since the original installation, You need a complete strip-out and recommission rather than piecemeal repair

Pool Hall AHU Troubleshooting & Survey, Marriott

Hotel / Leisure · Forest of Arden

Pool Hall AHU Troubleshooting & Survey, Marriott

Relevant if: Your pool hall AHU is failing to reach target temperature or humidity, The unit was recently installed or maintained but is still underperforming, You want an independent assessment before committing to replacement

01 / 07

Get in touch

Ready to Restore
Your AHU?

Tell us the make, model, and the issue you're experiencing. We respond within one working day with a practical assessment.

  • On-site condition survey by an experienced engineer
  • Fixed-price, itemised scope, no surprises
  • Works programmed around your operations
  • No obligation to proceed

Call us directly

01256 518170

Enquiry

We will aim to respond within 24 hours

Your details

Common questions

Frequently Asked Questions

Typically around 40% of a new unit. We provide a fixed-price, itemised quote after the survey. No commitment required before that.

This ranges from a few days to several weeks depending on the scope and size of the unit. We provide a clear programme at quotation stage.

Often not. Many refurbishments are staged so ventilation stays live. Where a shutdown is unavoidable, we programme it around your operational hours.

Typically 10–20+ years, confirmed at survey stage. If refurbishment isn't economically sound, we'll tell you honestly.

Yes. EC fan conversion, heat recovery, and controls integration can all be incorporated. Where the scope of works supports it, we work to HTM 03-01 benchmarks on healthcare sites. We'll confirm what's achievable at survey stage.

Regular filter changes and system inspections are essential to maintain the performance gains achieved during refurbishment.

When the structural frame is beyond economic repair. We assess this honestly: there is no incentive for us to favour one route over the other.

Engineer Insights

Technical guidance from real AHU projects

Occasional updates covering refurbishment strategy, energy reduction, fan upgrades, controls, and HVAC project guidance.